If you heat with a heat pump, you have probably seen the word AUX on the thermostat on a cold morning and wondered whether something was wrong. Usually nothing is. But aux heat that runs too often is one of the biggest reasons a winter electric bill jumps.
What aux heat actually is
Most heat pumps in Middle Tennessee have electric resistance strips in the indoor air handler. The heat pump moves heat from outdoors, which is efficient. The strips make heat from electricity directly, which is simple but costs roughly two to three times as much per unit of heat.
Aux heat means the thermostat has asked the strips to help the heat pump. Emergency heat means the strips are doing the whole job and the heat pump is locked out.
When aux should come on
There are three normal times:
- During defrost, when the heat pump briefly switches to cooling mode to melt frost off the outdoor coil.
- When outdoor temperatures drop below the heat pump's balance point, often somewhere in the 20s to low 30s for older single stage units.
- When you raise the thermostat several degrees at once and the system tries to catch up quickly.

When it is costing you
Aux heat that runs on 45 degree days, or every time the thermostat recovers from a setback, is wasting money. Common causes are a thermostat configured with default settings, a deep nighttime setback, a dirty outdoor coil or low refrigerant. Each makes the heat pump look like it cannot keep up.
Settings that help
Smart thermostats let you set an outdoor temperature lockout so the strips only run below a certain temperature. A shallow setback of two or three degrees at night is gentler on a heat pump than a deep one. If you like a cooler bedroom, recover gradually in the morning instead of jumping five degrees at 6 a.m.
Signs the strips themselves need attention
A burning dust smell on the first cold night is normal. A smell that lingers, a breaker that trips, or a house that falls behind on very cold nights can mean a failed element, sequencer or limit switch. Those parts get tested during a fall heat pump tune-up, which is the cheapest time to find them.
Questions about this topic
Should I switch to emergency heat when it gets cold?
Only if the heat pump has failed or a technician tells you to. Emergency heat runs on strips alone and can double the cost of heating while it is on.
Is it normal for steam to come off my heat pump in winter?
Yes. That is the defrost cycle melting frost, and the steam stops within a few minutes.